# TMP112 temperature sensor configuration options
# Copyright (c) 2016 Firmwave
# SPDX-License-Identifier: Apache-2.0
config TMP112
bool "TMP112 Temperature Sensor"
default y
depends on DT_HAS_TI_TMP112_ENABLED
select I2C
help
Enable the driver for Texas Instruments TMP112 High-Accuracy Digital
Temperature Sensors.
The TMP102 is compatible with the TMP112 but is less accurate and has
been successfully tested with this driver.
if TMP112
config TMP112_FULL_SCALE_RUNTIME
bool "Allow to set extended mode at runtime"
default y
help
When set extended mode can be selected using tmp112_attr_set
with SENSOR_ATTR_FULL_SCALE and value to set either 128 or 150
config TMP112_SAMPLING_FREQUENCY_RUNTIME
bool "Allow to set conversion rate at runtime"
default y
help
When set conversion rate can be set at runtime using sensor_attr_set
with SENSOR_ATTR_SAMPLING_FREQUENCY
endif # TMP112