The iso_rx_qos is only used for unicast audio, as
we do not set the RX QOS for the broadcast sink, nor
can a broadcast source set RX QOS.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
The `iso_qos` was only used for connected ISO, but
was placed outside of the CONFIG_BT_ISO_UNICAST
guard, such that for broadcast ISO-only it was unused.
Move the declaration and renamed to cis_iso_qos.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
This function retrieves TX sync information
(timestamp, offset, and sequence number)
from controller using HCI command HCI_LE_Read_ISO_TX_Sync.
Signed-off-by: Audun Korneliussen <audun.korneliussen@nordicsemi.no>
Rename the BT_ISO_INTERVAL_MIN/MAX to
BT_ISO_SDU_INTERVAL_MIN/MAX to avoid confusing this
the the ISO interval which is different from the SDU
interval.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
Add two new parameters to bt_iso_chan_send:
sn: The packet sequence number which shall be incremeted
per SDU interval.
ts: An optional timestamp value used to synchronize SDUs.
The sequence number in the API uses a 32-bit value even though
the sequence number for the HCI command is 16-bit. This is to
properly handle wrapping of sequence numbers, which is much
easier to do with additional bits allocated.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
The "iso connect" now also takes a security level option like
"iso listen", so that the central can easily encrypt
and connect a CIS in a single command.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
The ISO security implementation works by verifying
against the acl (bt_conn) sec_level field. The
bt_conn sec_level field is only available
if CONFIG_BT_SMP is enabled, so this commit
adds guards for all ISO security checks as well.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
The bluetooth ISO shell module now supports the newly
added central and peripheral ISO configs.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
In order to bring consistency in-tree, migrate all subsystems code to
the new prefix <zephyr/...>. Note that the conversion has been scripted,
refer to zephyrproject-rtos#45388 for more details.
Signed-off-by: Gerard Marull-Paretas <gerard.marull@nordicsemi.no>
Update the macro prototype to explicitly require the length of the
desired user data. Update all in-tree usage of this macro.
Signed-off-by: Jordan Yates <jordan.yates@data61.csiro.au>
Renames the struct from bt_iso_cig_create_param to
bt_iso_cig_param as the same struct can, without
modification, be used to update the CIG as well
(function to support that will come in a later commit).
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
A CIG may be updated later to include more CIS, and thus a slist
makes more sense.
The BIG doesn't need the change, but it makes more sense to
have similar handling for both.
This change also removes the requirement that the arrays
used to create the CIG/BIG need to static.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
Better group code specific for e.g. ISO broadcaster and
ISO sync receiver.
No code has been changed.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
Splitt he ISO broadcast config into broadcaster and
sync receiver. This will allow a device that only
wants to one of the roles to have a much more optimized
configuration.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
Add __printf_like modifier to validate strings used by shell.
Fixing warnings triggered by this change.
Signed-off-by: Krzysztof Chruscinski <krzysztof.chruscinski@nordicsemi.no>
Add a new struct that provides information to the upper
layer when accepting an connected isochronous stream.
The CIG ID and CIS ID makes it possible for the upper layer
to determine which ISO channels are "together" in a group.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
Add the BT_ISO_SDU_BUF_SIZE which can be used to declare
the TX buffers for ISO, similar to the BT_L2CAP_SDU_BUF_SIZE
macro for L2CAP.
This also updates the ISO samples to use this as well
updating the SDU check to use
CONFIG_BT_ISO_TX_MTU/CONFIG_BT_ISO_RX_MTU without
subtracting the BT_ISO_CHAN_SEND_RESERVE to make the
API more clear.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
To avoid hitting the following violation:
Violation to rule 5.7 (Tag name should be unique)
Replace the use of "shell" in the shell as an instance of a pointer to
const struct shell.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Update the name of the bt_conn pointers to make it clear
whether the connection pointers are ACL or ISO connections.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
Add a new Kconfig option, BT_ISO_UNICAST, to make it possible
either configure unicast only, broadcast only or both.
This results in some code being moved, but not modified, and
should not effect anything.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
The current iso commands in the shell only supports setting up
a bidirectional stream or unidirectional for central role.
Adding rx/tx/rxtx option to iso listen command to allow for
peripheral side configuration of an iso connection.
Signed-off-by: Casper Bonde <casper_bonde@bose.com>
The sequence number is needed in the appliaction layer to detect lost
packets in the ISO stream in cases where the timestamp is not included.
(Sequence number is mandatory to include where timestamp is optional).
The API for the public metadata have been moved to a public header file.
As the size of the ISO meta data exceeds the default 4 octets net_buf
user_data the public ISO metadata have been moved into a seperate array.
The internal metadata is still stored in net_buf user_data.
This also fixed the user_data overflow on 32 bit systems, caused by
writing the ts into user_data on index 4 to 7, which is outside the 4
allocated bytes.
Signed-off-by: Casper Bonde <casper_bonde@bose.com>
When broadcasting with ISO it would wrongly use the tx_pool
defined for CIS, instead of the broadcast TX pool.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
Channel direction was actually a source of confusion since the spec does
actually define the data path direction from controller point of view
meaning input actually means transmit and output receive, also direction
can be configured with different QoS settings.
To make these APIs less confusing and allow QoS to be configured
independently they are now split into RX (receiving) and TX
(transmission) settings including its data path.
Signed-off-by: Luiz Augusto von Dentz <luiz.von.dentz@intel.com>
The SCA (sca) field of bt_iso_chan_qos did not give much
information about the expected values or what they meant,
nor any information about what the value perhaps should be.
Updated the description and the ISO shell.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
Added initial support for BIS (broadcast ISO stream), which
adds support for creating BISes as both broadcaster and receiver,
as well as managing and creating BIGs.
Extends PA sync to handle BIGInfo adveritising reports.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
`iso send` may take an optional "count" parameter but the
number of optional arguments was incorrect.
Signed-off-by: Emil Gydesen <emil.gydesen@nordicsemi.no>
This adds iso shell module which we can be used to exercise ISO related
APIs:
iso - Bluetooth ISO shell commands
Subcommands:
bind :[dir] [interval] [packing] [framing] [latency] [sdu]
[phy] [rtn]
connect :Connect ISO Channel
listen :[security level]
send :Send to ISO Channel
disconnect :Disconnect ISO Channel
Signed-off-by: Luiz Augusto von Dentz <luiz.von.dentz@intel.com>