zephyr/samples/sensor/ams_iAQcore
Gerard Marull-Paretas c7b5b3c419 samples: migrate includes to contain <zephyr/...> prefix
In order to bring consistency in-tree, migrate all samples to the use
the new prefix <zephyr/...>. Note that the conversion has been scripted:

```python
from pathlib import Path
import re

EXTENSIONS = ("c", "h", "cpp", "rst")

for p in Path(".").glob("samples/**/*"):
    if not p.is_file() or p.suffix and p.suffix[1:] not in EXTENSIONS:
        continue

    content = ""
    with open(p) as f:
        for line in f:
            m = re.match(r"^(.*)#include <(.*)>(.*)$", line)
            if (m and
                not m.group(2).startswith("zephyr/") and
                (Path(".") / "include" / "zephyr" / m.group(2)).exists()):
                content += (
                    m.group(1) +
                    "#include <zephyr/" + m.group(2) +">" +
                    m.group(3) + "\n"
                )
            else:
                content += line

    with open(p, "w") as f:
        f.write(content)
```

Signed-off-by: Gerard Marull-Paretas <gerard.marull@nordicsemi.no>
2022-05-06 11:29:59 +02:00
..
src samples: migrate includes to contain <zephyr/...> prefix 2022-05-06 11:29:59 +02:00
CMakeLists.txt
iaq_core.overlay
prj.conf
README.rst
sample.yaml

.. _ams_iaqcore:

ams iAQcore Indoor air quality sensor
#####################################

Overview
********

This sample application demonstrates how to use the ams iAQcore sensor to
measure CO2 equivalent and VOC. The CO2 value is a predicted value derived from
VOC. The values are fetched and printed every second.

Building and Running
********************

This sample application uses the sensor connected to the i2c stated in the
iaq_core.overlay file.
Flash the binary to a board of choice with a sensor connected.
This sample can run on every board with i2c.
For example build for a nucleo_f446re board:

.. zephyr-app-commands::
   :zephyr-app: samples/sensor/ams_iAQcore
   :board: nucleo_f446re
   :goals: build flash
   :compact:

Sample Output
=============

.. code-block:: console

    device is 0x20001a08, name is IAQ_CORE
    Co2: 882.000000ppm; VOC: 244.000000ppb
    Co2: 863.000000ppm; VOC: 239.000000ppb
    Co2: 836.000000ppm; VOC: 232.000000ppb