Some of control procedures has set ctx->rx_opcode in rp_comm_tx function to values that state there is an expected PDU. This is not always true. In case of procedures that do not expect any response from remote device, the ctx->rx_opcode should be set to PDU_DATA_LLCTRL_TYPE_UNUSED. In the worst cases scenario, when the same control procedure is executed locally and remotely, correct response PDU may cause an assertion in ull_cp_rx. It could happen because of wrong ctx->rx_opcode value. A packet with opcode that is set in remote and local control procedure context rx_opcode will be treated as expected value for both. That is a situation that cannot happen. The commit changes the assignments of rx_opcode to fix the problem. Signed-off-by: Piotr Pryga <piotr.pryga@nordicsemi.no> |
||
|---|---|---|
| .. | ||