zephyr/samples/sensor/th02
Kumar Gala 5d36157c7c sensors: Remove unnecessary Kconfig setting of sensors
Sensor Kconfig sybmols should be enabled if CONFIG_SENSOR=y
and the devicetree node for the sensor is enabled.  We can
remove explicitly enabling specific sensor drivers in .conf
files.

Signed-off-by: Kumar Gala <galak@kernel.org>
2022-07-25 15:18:56 +02:00
..
boards samples: sensors: Remove label property from devicetree overlays 2022-07-19 08:23:35 -05:00
src samples: th02: simplify sample and use DEVICE_DT_GET_ONE 2022-07-25 09:39:51 +02:00
CMakeLists.txt
prj.conf sensors: Remove unnecessary Kconfig setting of sensors 2022-07-25 15:18:56 +02:00
README.rst
sample.yaml samples: sensor: th02: add Grove LCD compatible to the filter 2022-02-22 11:58:33 -08:00

.. _th02-sample:

TH02: Temperature and Humidity Monitor
######################################

Overview
********
This sample periodically reads temperature and humidity from the Grove
Temperature & Humidity Sensor (TH02) and display the results on the Grove LCD
display.


Requirements
************

This sample uses the TH02 sensor and the grove LCD display. Both devices are
controlled using the I2C interface.

More details about the sensor and the display can be found here:

- `Grove Temperature And Humidity`_
- `Grove LCD Module`_

Wiring
******

The easiest way to get this wired is to use the Grove shield and connect both
devices to I2C. No additional wiring is required. Depending on the board you are
using you might need to connect two 10K ohm resistors to SDL and and SDA (I2C).
The LCD display requires 5 volts, so the voltage switch on the shield needs to
be on 5v.


References
**********

 - TH02: http://www.datasheetspdf.com/mobile/748107/TH02.html


.. _Grove LCD Module: http://wiki.seeed.cc/Grove-LCD_RGB_Backlight/
.. _Grove Temperature And Humidity: http://wiki.seeed.cc/Grove-TemptureAndHumidity_Sensor-High-Accuracy_AndMini-v1.0/