.. zephyr:code-sample:: lps22hh
:name: LPS22HH Temperature and Pressure Sensor
:relevant-api: sensor_interface
Get pressure and temperature data from an LPS22HH sensor (polling & trigger mode).
Overview
********
This sample periodically reads pressure from the LPS22HH MEMS pressure
sensor and displays it on the console.
Requirements
************
This sample uses the LPS22HH sensor controlled using the I2C interface.
References
**********
- LPS22HH: https://www.st.com/en/mems-and-sensors/lps22hh.html
Building and Running
********************
This project outputs sensor data to the console. It requires an LPS22HH
sensor, which is present on the X-NUCLEO-IKS01A3 shield.
.. zephyr-app-commands::
:zephyr-app: samples/sensor/lps22hh
:board: nrf52dk/nrf52832
:shield: x_nucleo_iks01a3
:goals: build
:compact:
Sample Output
=============
.. code-block:: console
Configured for triggered collection at 1 Hz
Observation: 1
Pressure: 97.474 kPa
Temperature: 22.19 C
Observation: 2
Pressure: 97.466 kPa
Temperature: 22.21 C
Observation: 3
Pressure: 97.473 kPa
Temperature: 22.21 C
Observation: 4
Pressure: 97.455 kPa
Temperature: 22.21 C
<repeats endlessly every second>