.. _disk_nvme:
|
|
|
|
NVMe
|
|
####
|
|
|
|
NVMe is a standardized logical device interface on PCIe bus exposing storage devices.
|
|
|
|
NVMe controllers and disks are supported. Disks can be accessed via the :ref:`Disk Access API <disk_access_api>` they expose
|
|
and thus be used through the :ref:`File System API <file_system_api>`.
|
|
|
|
Driver design
|
|
*************
|
|
|
|
The driver is sliced up in 3 main parts:
|
|
|
|
- NVMe controller: :zephyr_file:`drivers/disk/nvme/nvme_controller.c`
|
|
- NVMe commands: :zephyr_file:`drivers/disk/nvme/nvme_cmd.c`
|
|
- NVMe namespace: :zephyr_file:`drivers/disk/nvme/nvme_namespace.c`
|
|
|
|
Where the NVMe controller is the root of the device driver. This is the one that will get device driver instances.
|
|
Note that this is only what DTS describes: the NVMe controller, and none of its namespaces (disks).
|
|
The NVMe command is the generic logic used to communicate with the controller and the namespaces it exposes.
|
|
Finally the NVMe namespace is the dedicated part to deal with an actual namespace which, in turn, enables applications
|
|
accessing each ones through the Disk Access API :zephyr_file:`drivers/disk/nvme/nvme_disk.c`.
|
|
|
|
If a controller exposes more than 1 namespace (disk), it will be possible to raise the amount of built-in namespace support
|
|
by tweaking the configuration option CONFIG_NVME_MAX_NAMESPACES (see below).
|
|
|
|
Each exposed disk, via it's related disk_info structure, will be distinguished by its name which is inherited from
|
|
it's related namespace. As such, the disk name follows NVMe naming which is nvme<k>n<n> where k is the controller number
|
|
and n the namespame number. Most of the time, if only one NVMe disk is plugged into the system, one will see 'nvme0n0' as
|
|
an exposed disk.
|
|
|
|
NVMe configuration
|
|
******************
|
|
|
|
DTS
|
|
===
|
|
|
|
Any board exposing an NVMe disk should provide a DTS overlay to enable its use within Zephyr
|
|
|
|
.. code-block:: devicetree
|
|
|
|
#include <zephyr/dt-bindings/pcie/pcie.h>
|
|
/ {
|
|
pcie0 {
|
|
nvme0: nvme0 {
|
|
compatible = "nvme-controller";
|
|
vendor-id = <VENDOR_ID>;
|
|
device-id = <DEVICE_ID>;
|
|
status = "okay";
|
|
};
|
|
};
|
|
};
|
|
|
|
Where VENDOR_ID and DEVICE_ID are the ones from the exposed NVMe controller.
|
|
|
|
Options
|
|
=======
|
|
|
|
* :kconfig:option:`CONFIG_NVME`
|
|
|
|
Note that NVME requires the target to support PCIe multi-vector MSI-X in order to function.
|
|
|
|
* :kconfig:option:`CONFIG_NVME_MAX_NAMESPACES`
|
|
|
|
Important note for users
|
|
************************
|
|
|
|
NVMe specifications mandate the data buffer to be placed in a dword (4 bytes) aligned address.
|
|
While this is not a problem for advanced OS managing virtual memory and dynamic allocations
|
|
below the user processes, this can become an issue in Zephyr as soon as buffer addresses
|
|
map directly to physical memory.
|
|
|
|
At this stage then, it is up to the user to make sure the buffer address being provided to
|
|
:c:func:`disk_access_read` and :c:func:`disk_access_write` are dword aligned.
|