zephyr/drivers/sensor/ens210/Kconfig
Kumar Gala df81fef944 drivers: sensor: Convert Kconfig bus 'depends on' to 'select'
This change in pattern is meant to address a misconfiguration issue
that can occur for sensors that support being on multiple busses
like I2C & SPI.

For example, you can have a configuration in which such a sensor is
on the I2C bus in the devicetree and the sensor is enabled.  However
the application configuration enables CONFIG_SPI=y and CONFIG_I2C=n
and this will cause the sensor driver to be built by default, however
since we don't have the I2C bus enabled the driver will not compile
correctly.

Previously we had been adding to board Kconfig.defconfig something
like:

	config I2C
		default y if SENSOR

This pattern doesn't scale well and may differ from what an application
specific need/use is.

So instead move to a pattern in which we leave the default enablement
up to the devicetree "status" property for the sensor.  We then have
the Kconfig move from 'depends on <BUS>' to 'select <BUS>' and in
the case of drivers that support multiple busses we have the Kconfig
be: 'select <BUS> if $(dt_compat_on_bus,$(<DT_COMPAT>),<BUS>) for
each bus type the sensor supports.

This removes the need to add Kconfig logic to each board and enables
the bus subsystem and bus controller driver if the sensor requires
it by default in the build system.

Fixes: #48518

Signed-off-by: Kumar Gala <galak@kernel.org>
2022-08-08 06:58:18 +01:00

61 lines
1.6 KiB
Plaintext

# ENS210 Digital Temperature and Humidity sensor configuration options
# Copyright (c) 2018 Alexander Wachter.
# SPDX-License-Identifier: Apache-2.0
menuconfig ENS210
bool "ENS210 Digital Temperature and Humidity sensor"
default y
depends on DT_HAS_AMS_ENS210_ENABLED
select I2C
help
Enable driver for ENS210 Digital Temperature and Humidity sensor.
if ENS210
choice
prompt "Temperature measurement mode"
default ENS210_TEMPERATURE_CONTINUOUS
help
Enable/disable temperature measurements and set measurement mode.
config ENS210_TEMPERATURE_OFF
bool "Disable temperature measurements"
config ENS210_TEMPERATURE_SINGLE
bool "Temperature measurements in single shot mode"
config ENS210_TEMPERATURE_CONTINUOUS
bool "Temperature measurements in continuous mode"
endchoice
choice
prompt "Humidity measurement mode"
default ENS210_HUMIDITY_CONTINUOUS
help
Enable/disable relative humidity measurements and set measurement mode.
config ENS210_HUMIDITY_OFF
bool "Disable relative humidity measurements"
config ENS210_HUMIDITY_SINGLE
bool "Relative humidity measurements in single shot mode"
config ENS210_HUMIDITY_CONTINUOUS
bool "Relative humidity measurements in continuous mode"
endchoice
config ENS210_CRC_CHECK
bool "CRC Check"
default y
help
Check the crc value after data reading.
config ENS210_MAX_STAT_RETRIES
int "Number of status read retries"
default 4
help
Number of retries when status reading failed or device not ready.
config ENS210_MAX_READ_RETRIES
int "Number of value reading retries"
default 4
help
Number of retries when value reading failed, value not valid
or crc not ok.
endif # ENS210