Add a fixture to run the sample only when the DHT sensor HX330x is present (shield) on the nucleo_f40re board 'fixture_i2c_hs300x' The stm32f401 Nucleo board itself has no sensor mounted Signed-off-by: Francois Ramu <francois.ramu@st.com>
60 lines
1.6 KiB
ReStructuredText
60 lines
1.6 KiB
ReStructuredText
.. _dht_polling:
|
|
|
|
Generic Digital Humidity Temperature sensor polling sample
|
|
##########################################################
|
|
|
|
Overview
|
|
********
|
|
|
|
This sample application demonstrates how to use digital humidity temperature
|
|
sensors.
|
|
|
|
Building and Running
|
|
********************
|
|
|
|
This sample supports up to 10 humidity/temperature sensors. Each sensor needs to
|
|
be aliased as ``dhtN`` where ``N`` goes from ``0`` to ``9``. For example:
|
|
|
|
.. code-block:: devicetree
|
|
|
|
/ {
|
|
aliases {
|
|
dht0 = &hs300x;
|
|
};
|
|
};
|
|
|
|
|
|
Make sure the aliases are in devicetree.
|
|
|
|
It also requires a correct fixture setup when the sensor is present.
|
|
For the correct execution of that sample in twister, add into boards's
|
|
map-file next fixture settings::
|
|
|
|
- fixture: fixture_i2c_hs300x
|
|
|
|
|
|
Then build and run with:
|
|
|
|
.. zephyr-app-commands::
|
|
:zephyr-app: samples/sensor/dht_polling
|
|
:board: <board to use>
|
|
:goals: build flash
|
|
:compact:
|
|
|
|
Sample Output
|
|
=============
|
|
|
|
.. code-block:: console
|
|
|
|
hs300x@44: temp is 25.31 °C humidity is 30.39 %RH
|
|
hs300x@44: temp is 25.51 °C humidity is 30.44 %RH
|
|
hs300x@44: temp is 25.51 °C humidity is 30.37 %RH
|
|
hs300x@44: temp is 25.51 °C humidity is 30.39 %RH
|
|
hs300x@44: temp is 25.31 °C humidity is 30.37 %RH
|
|
hs300x@44: temp is 25.31 °C humidity is 30.35 %RH
|
|
hs300x@44: temp is 25.51 °C humidity is 30.37 %RH
|
|
hs300x@44: temp is 25.51 °C humidity is 30.37 %RH
|
|
hs300x@44: temp is 25.51 °C humidity is 30.39 %RH
|
|
hs300x@44: temp is 25.51 °C humidity is 30.44 %RH
|
|
hs300x@44: temp is 25.51 °C humidity is 30.53 %RH
|