# Common fields for CAN controllers
include: base.yaml
properties:
bus-speed:
type: int
required: true
description: bus speed in Baud/s
sjw:
type: int
required: true
description: Resynchronization jump width (ISO 11898-1)
prop-seg:
type: int
required: false
description: Time quantums of propagation segment (ISO 11898-1)
phase-seg1:
type: int
required: false
description: Time quantums of phase buffer 1 segment (ISO 11898-1)
phase-seg2:
type: int
required: false
description: Time quantums of phase buffer 2 segment (ISO 11898-1)
sample-point:
type: int
required: false
description: >
Sample point in permille.
This param is required if segments are not given.
If the sample point is given, the segments are ignored.