This reverts commit 7f51907fda.
The problem with setting the priority at the highest priority possible
is that when the IPC is under high traffic, the WQ could starve the
scheduler.
Move back to a more sane preemptive priority as default value.
Signed-off-by: Carlo Caione <ccaione@baylibre.com>
Recently OpenAMP introduced the possibility to set the sizes for TX and
RX buffers per created instance. Expose this also to Zephyr users by
using a DT property "zephyr,buffer-size".
For the sake of simplicity use the same DT property to set the buffer
size for both TX and RX buffers.
Signed-off-by: Carlo Caione <ccaione@baylibre.com>
In 92d8329d5b a new DT property was introduced to set the WQ priority
of the instance. The fallback value when the property was not present
was arbitrarily set to <0 PRIO_PREEMPT>.
The problem is that this value is actually changing the behaviour for
the code that is not explicitly setting the DT property, breaking in
some cases the existing code.
Move the default value to <0 PRIO_COOP> to give the old code a
consistent behaviour before and after the 92d8329d5b commit.
Signed-off-by: Carlo Caione <ccaione@baylibre.com>
Instead of having one single WQ per backend, move to one WQ per
instance instead and add a new "zephyr,priority" property in the DT to
set the WQ priority of the instance. Fix the sample as well.
Signed-off-by: Carlo Caione <ccaione@baylibre.com>
This commit adds ipc backend, that relies on simple
inter core messaging buffer also added by this commit.
This backend is configurable with DT overlay. Each
ipc instance could be defined with ipc-icmsg commpatible.
Signed-off-by: Emil Obalski <emil.obalski@nordicsemi.no>
Introduce a new RPMsg with static VRINGs backend. This new backend makes
easy to generate and use IPC instances backed by OpenAMP using the DT.
Each instance is defined in the DT as (for example):
ipc: ipc {
compatible = "zephyr,ipc-openamp-static-vrings";
shm = <&sram_ipc0>;
mboxes = <&mbox 0>, <&mbox 1>;
mbox-names = "tx", "rx";
role = "primary";
status = "okay";
};
It is then possible to register an send data through endpoints using the
IPC service APIs.
Signed-off-by: Carlo Caione <ccaione@baylibre.com>