Commit Graph

6 Commits

Author SHA1 Message Date
Gerard Marull-Paretas
c7b5b3c419 samples: migrate includes to contain <zephyr/...> prefix
In order to bring consistency in-tree, migrate all samples to the use
the new prefix <zephyr/...>. Note that the conversion has been scripted:

```python
from pathlib import Path
import re

EXTENSIONS = ("c", "h", "cpp", "rst")

for p in Path(".").glob("samples/**/*"):
    if not p.is_file() or p.suffix and p.suffix[1:] not in EXTENSIONS:
        continue

    content = ""
    with open(p) as f:
        for line in f:
            m = re.match(r"^(.*)#include <(.*)>(.*)$", line)
            if (m and
                not m.group(2).startswith("zephyr/") and
                (Path(".") / "include" / "zephyr" / m.group(2)).exists()):
                content += (
                    m.group(1) +
                    "#include <zephyr/" + m.group(2) +">" +
                    m.group(3) + "\n"
                )
            else:
                content += line

    with open(p, "w") as f:
        f.write(content)
```

Signed-off-by: Gerard Marull-Paretas <gerard.marull@nordicsemi.no>
2022-05-06 11:29:59 +02:00
Constantin Krischke
8ee675946c modbus: stop bits can now be set individually in client mode
Added the stop_bits_client parameter to the modbus_serial_param struct.
Being able to configure the number of stop bits for the client
independently from the parity setting, allows to support connecting to
modbus server that do not follow the MODBUS over Serial Line Specification
and Implementation Guide.

Signed-off-by: Constantin Krischke <constantin.krischke@lemonbeat.com>
Signed-off-by: Jan Geldmacher <jan.geldmacher@lemonbeat.com>
2022-03-24 08:23:17 -04:00
Johann Fischer
4ff616b647 modbus: rework interface configuration
Use commot parameter structure to configure server
or client interfaces.

Signed-off-by: Johann Fischer <johann.fischer@nordicsemi.no>
2021-03-19 15:50:21 +01:00
Johann Fischer
699b2cdf9b modbus: remove RTU from configuration and headers
Remove RTU from configuration and headers

Signed-off-by: Johann Fischer <johann.fischer@nordicsemi.no>
2021-03-19 15:50:21 +01:00
Johann Fischer
ed0629f623 modbus: rename MODBUS RTU API to common MODBUS API
Rename MODBUS RTU API to common MODBUS API.

Signed-off-by: Johann Fischer <johann.fischer@nordicsemi.no>
2021-03-19 15:50:21 +01:00
Johann Fischer
fef70aa494 samples: add Modbus RTU client sample
Add Modbus RTU client sample.

Signed-off-by: Johann Fischer <j.fischer@phytec.de>
2021-03-19 15:50:21 +01:00