The function ina219_set_msr_delay always returns zero, indicating success.
Therefore, the error check on its return value is unnecessary and can be
removed.
Signed-off-by: Tarang Raval <tarang.raval@siliconsignals.io>
Before communicating with the device, the driver needs to wait 300ms. This
moves all communication with the device from init to configure, such
that this delay can be avoided on startup by using zephyr,lazy-load.
Signed-off-by: Tobias Pisani <mail@topisani.dev>
This commit adds support for INA236 into the existing INA230 driver.
These two chips are similar enough to share most of the code.
The device can be defined the same way as INA230 and we only have
the extra option to select the high-precision mode.
```
ina236: ina236@40 {
status = "okay";
compatible = "ti,ina236", "ti,ina230";
reg = <0x40>;
adc-mode = "Bus and shunt voltage continuous";
vbus-conversion-time-us = <1100>;
vshunt-conversion-time-us = <1100>;
avg-count = <1>;
current-lsb-microamps = <1000>;
rshunt-micro-ohms = <15000>;
alert-gpios = <&gpiod 0 GPIO_ACTIVE_LOW>;
high-precision;
};
```
Signed-off-by: Tomáš Juřena <jurenatomas@gmail.com>
TI tmp1075 driver implemented based on tmp108 driver.
The driver initializes the sensor based on the DTS.
Added tmp1075 example overlay file to thermometer sample.
All you need to do to use the sensor is to connect the I2C and
optionally interrupt line.
To see default DTS configuration option inspect `ti,tmp1075.yaml`
bindings file and sensor spec.
Signed-off-by: Paweł Czaplewski <pawel.czaplewski@arrow.com>
Adds support for setting the operating mode of the TMP116/7 sensor to
either shutdown, continuous conversion or one-shot mode.
Signed-off-by: Ian Morris <ian.d.morris@outlook.com>
Add missing braces to comply with MISRA C:2012 Rule 15.6 and
also following Zephyr's style guideline.
Signed-off-by: Pisit Sawangvonganan <pisit@ndrsolution.com>
Tmp114 has an average function, according to the datasheet this is
default disabled. Add attribute to enable this feature.
Signed-off-by: Fredrik Gihl <fgihl@hotmail.com>
The TMAG3001 is quite similar to the tmag5273 and can be used with just
some small modifications.
Signed-off-by: Fabian Pflug <fabian.pflug@grandcentrix.net>
Adds support for setting the number of conversion results that are
collected and averaged before updating the temperature register.
Signed-off-by: Ian Morris <ian.d.morris@outlook.com>
Add a driver for the National/TI LM95234 Quad Remote Diode and Local
Temperature Sensor with SMBus Interface and TruTherm Technology.
Signed-off-by: Robert Hancock <robert.hancock@calian.com>
If an immediate return on error is used, an additional result check in
sample_fetch can be neglected. Since they are now treated as errors,
also changed logging type.
Signed-off-by: Juliane Schulze <juliane.schulze@deveritec.com>
Only show the tmp112 runtime options when the tmp112 driver is enabled,
otherwise the option is confusing and does not appear hierarchically in
menuconfig.
Signed-off-by: Aurelien Jarno <aurelien@aurel32.net>
Add device driver for TI TMP114 I2C temperature sensor.
The driver only support basic functionality, i.e. fetch temperature
using default values.
Datasheet:
https://www.ti.com/lit/ds/symlink/tmp114.pdf
Signed-off-by: Fredrik Gihl <fgihl@hotmail.com>