Commit Graph

7 Commits

Author SHA1 Message Date
Jordan Yates
1637443dc0 sensor: current_amp: request calibration
Request calibration on ADC samples to improve the accuracy of the ADC
outputs and therefore the final measured current.

Signed-off-by: Jordan Yates <jordan@embeint.com>
2024-10-15 19:07:21 +01:00
Jordan Yates
4361c96c48 adc: current_sense_amplifier: resistance in milli-ohms
Change the unit of the sense resistor in the devicetree binding from
micro-ohms to milli-ohms. This is done for three reasons.

Firstly, the maximum value resistor that can currently be represented
is 4.2 kOhms, due to the limitation of devicetree properties to 32 bits.

Secondly, storing the resistance at such a high resolution makes
overflows much more likely when the desired output unit is micro-amps,
not milli-amps.

Finally, micro-ohms, are an unnecessarily precise unit for the purpose
of these calculations, and a resolution that is not realistic to
achieve. The high resistor resolution results in large divisors that
reduce the resolution of outputs. Unlike resistors characterised down to
the micro-ohm, devices wanting to measure micro-amps are actually
realistic.

Signed-off-by: Jordan Yates <jordan@embeint.com>
2024-10-14 13:05:07 +02:00
Nick Ward
49d09ecb28 sensor: current_amp: fix fractional value
It needs to be x1000

Also correct the units used in the log

Signed-off-by: Nick Ward <nix.ward@gmail.com>
2024-06-11 20:11:53 +03:00
Jordan Yates
d725666b2c sensor: convert ADC depends on to select
When a sensor that depends on an ADC is enabled in devicetree, enable
the ADC subsystem. ADC is roughly equivalent to a bus for these sensors
(the mechanism through which data is transferred), which had the same
conversion applied in #48707.

The same benefits apply here, namely removing the need for the following
pattern in board `.kconfig` files:
```
configdefault ADC
    default y if SENSOR
```

Signed-off-by: Jordan Yates <jordan@embeint.com>
2024-05-16 13:31:32 +02:00
Nick Ward
3dba54b92d drivers: current sense amp: add pm
Enable power management for current sense amp.

Signed-off-by: Nick Ward <nix.ward@gmail.com>
2023-09-25 11:23:45 -05:00
Nick Ward
ead0c4f865 drivers: adc: use adc_read_dt api
Where struct adc_dt_spec is in use use adc_read_dt().

Signed-off-by: Nick Ward <nix.ward@gmail.com>
2023-09-25 09:52:16 +02:00
Nick Ward
17f2046821 drivers: sensor: current_amp: add driver
Add current sense amplifier driver.

Implements https://github.com/zephyrproject-rtos/zephyr/issues/60415

Co-authored-by: Marco Argiolas <marco.argiolas@ftpsolutions.com.au>

Signed-off-by: Nick Ward <nix.ward@gmail.com>
2023-09-13 12:05:52 +02:00