Adds the const qualifier to the internal api for adding and removing
virtual addresses, to allow them to accept const hardcoded values in
tests.
Signed-off-by: Trond Einar Snekvik <Trond.Einar.Snekvik@nordicsemi.no>
The mesh settings.c module is a giant piece of code responsible for
storing the mesh stack configuration. Such approach makes it difficult
to control the data to be stored, breaks the stack modules'
encapsulation by forcing them to reveal the internal kitchen, which
leads to unpleasant issues such as #19799.
This commit moves the responsibility of storing the configuration
to corresponding modules while keeping control of the moment of storing
the configuration and of starting the stack after the settingss loading
is completed.
This doesn't introduce any abstraction between the mesh settings.c and
other modules as it will add more complexity and overhead than necessary
for the actual task.
Fixes#19850
Signed-off-by: Pavel Vasilyev <pavel.vasilyev@nordicsemi.no>
Encapsulates the Heartbeat state and functionality in a separate
heartbeat module, removing all manipulation of the heartbeat state from
the transport and config server modules.
Signed-off-by: Trond Einar Snekvik <Trond.Einar.Snekvik@nordicsemi.no>
Moves the virtual address labels to the transport layer, disconnecting
them from the configuration server.
Signed-off-by: Trond Einar Snekvik <Trond.Einar.Snekvik@nordicsemi.no>
This is a major refactoring of the handling of the cryptographic
material of both the network and transport layers. The aim is to
encapsulate the key object manipulation, and improve overall modularity.
Pulls Applications and Subnets out of the bt_mesh and into separate
modules, with static storage types on the data. This has several
side-effects:
- The Config Server no longer operates directly on the bt_mesh.subs and
bt_mesh.apps lists, but goes through a public configuration interface,
following the pattern set in #27908.
- All iteration through the keys is done through iteration APIs
- Key resolution on RX and TX is centralized.
- Changes to the keys triggers events the other modules can register
handlers for.
- Friendship credentials are stored in the lpn and friend structures.
Part of #27842.
Signed-off-by: Trond Einar Snekvik <Trond.Einar.Snekvik@nordicsemi.no>
Starts the periodic heartbeat publish period at the end of the
publication, instead of at the ordering time. This ensures that the
heartbeat period doesn't get shortened by other enqueued messages.
Signed-off-by: Trond Einar Snekvik <Trond.Einar.Snekvik@nordicsemi.no>
Allocates segmented message buffers as slabs in a common pool for RX and
TX. This reduces memory requirements for both TX and RX, as TX messages
can be stored without the network and advertising buffer overhead, and
RX can use only the slabs it needs, instead of allocating a full size
segmented message. This approach also removes the need for decrypting
the segments for each retransmission, reducing overall processing load.
Slab based segmentation for tx also introduces queuing of segmented
messages, which allows the application layer to send multiple messages
to the same destination without violating Bluetooth Mesh specification
v1.0.1, section 3.6.4.1. This mechanism is provided through a flag that
blocks segmented messages to a destination which a message is already
being sent to until the previous message finishes.
This changes the SDU size configuration to a symmetrical
RX_SEG_MAX/TX_SEG_MAX pair of configurations, plus a new segment pool
side configuration. It also removes the binding between the TX_SEG_MAX
config and the advertising buffers, reducing the minimum advertising
buffer count from 6 to 3.
Signed-off-by: Trond Einar Snekvik <Trond.Einar.Snekvik@nordicsemi.no>
The Friend queue uses the message SeqAuth to determine whether the
message is already in the queue. To facilitate this, the SeqAuth is
passed around as a pointer throughout the transport modules. In the
bt_mesh_ctl_send functions, this parameter is also exposed in the API,
but the internal usage is inconsistent and buggy. Also, no one actually
uses this parameter.
- Removes seq_auth param from bt_mesh_ctl_send, instead passing NULL
directly to the friend module, to enforce its addition to the queue.
- Makes the seq_auth pointer const throughout the friend module.
Signed-off-by: Trond Einar Snekvik <Trond.Einar.Snekvik@nordicsemi.no>
Make it possible to provision devices over advertising bearer (PB-ADV).
Many messages in the provisioning protocol are the same for provisioner
and device so much of the code could be reused by only changing when
they are expected to arrive.
This introduces to concept of local and remote device keys. The models
for cfg_cli and cfg_srv have been updated to reflect this concept. Both
the send and receive path in the transport layer have been updated to
support encrypting/decrypting with local and remote device keys.
When a node has been provisioned it is stored in bt_mesh_net.nodes. If
CONFIG_BT_SETTINGS is enabled, they are also saved to settings. If the
callback node_added in bt_mesh_prov has been set, it will be called for
every node that gets provisioned. This includes when they are retrieved
from settings.
The configuration CONFIG_BT_MESH_NODE_COUNT controls how many nodes that
can be provisioned.
Signed-off-by: Tobias Svehagen <tobias.svehagen@gmail.com>
Provides a utility function for getting an application key given a
subnet and an app ID. Primary use-case in friendship re-encryption.
Signed-off-by: Trond Einar Snekvik <Trond.Einar.Snekvik@nordicsemi.no>
Makes a define for the seqzero 13-bit mask in transport, and exposes it
in the header for use in the friend module.
Signed-off-by: Trond Einar Snekvik <Trond.Einar.Snekvik@nordicsemi.no>
The heartbeat is a transport layer feature, so move it to transport.c.
This also opens the way to properly fix Friendship-established/lost
triggering for LPN role.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
We've already got GATT services in subsys/bluetooth/services so
subsys/bluetooth/mesh is a more natural place. Aditionally this aims
to fix the Kconfig dependencies to be able to use mesh together with
BT_CUSTOM (i.e. a custom, potentially non-HCI, host stack).
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>