This fixes the limitation of sending an extended CAN frame.
Because the default value of `CONFIG_SHELL_ARGC_MAX` is 12 the maximum
number of bytes for an extended CAN frame is 7.
Increasing it to 13 to allow all 8 bytes to be sent from the shell.
Tested on nucleo_f767zi.
Signed-off-by: Cezar Burlacu <cezar@embeddedp.ro>
CAN_MCP2515_MAX_FILTER is not needed anymore and was probably just a
misunderstanding. Aligned it with the other CAN drivers.
This also was the last difference in the mcp2515 specific config for the
can sample, so that can be deleted as well.
Signed-off-by: Karsten Koenig <karsten.koenig.030@gmail.com>
Reordering of the struct elements to match the Linux format.
The __packed() is not necessary anymore.
std_id and ext_id is merged to id in the frame and filter.
Additionally, the frames are ready for CAN-FD.
Signed-off-by: Alexander Wachter <alexander@wachter.cloud>
The previous API can't change the sampling-point and only allowed
bitrates that fit the time segments.
The new API allows for shifting the sampling-point and adjusts the
number of time quantum in a bit to all more possible bitrates.
The functions to calculate the timings are moved to the can_common file.
They can be used for all drivers.
Signed-off-by: Alexander Wachter <alexander@wachter.cloud>
Now that device_api attribute is unmodified at runtime, as well as all
the other attributes, it is possible to switch all device driver
instance to be constant.
A coccinelle rule is used for this:
@r_const_dev_1
disable optional_qualifier
@
@@
-struct device *
+const struct device *
@r_const_dev_2
disable optional_qualifier
@
@@
-struct device * const
+const struct device *
Fixes#27399
Signed-off-by: Tomasz Bursztyka <tomasz.bursztyka@linux.intel.com>
This provides a better error message when building with CMake and
forgetting ZEPHYR_BASE or not registering Zephyr in the CMake package
registry. See parent commit for more details (split from parent for
better readability).
Signed-off-by: Marc Herbert <marc.herbert@intel.com>
Convert all canbus related API/samples/tests/subsys
to the new timeout API with k_timeout_t.
Signed-off-by: Alexander Wachter <alexander@wachter.cloud>
This commit renames the CAN sample directory name from `CAN` to `can`
to be consistent with others.
Noting that the CAN driver test directory is named `tests/drivers/can`,
we have no excuse for naming the CAN driver sample directory
`samples/drivers/CAN`.
Signed-off-by: Stephanos Ioannidis <root@stephanos.io>