Fix radio_tmr_start_now from returning delayed start time
under race conditions where the capture time has elapsed but
the compare has triggered at the same time.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Workaround for nRF52 anomalies 102, 106, and 107 was applied also for
SoCs that were not affected with those, namely nRF52811 and nRF52840.
Since the side effect of this workaround is reduction of sensitivity,
this was highly undesirable.
This commit uses dedicated functions provided by MDK for checking if
a given anomaly applies to the used SoC (and its actual revision) so
that the workaround is applied only when it is really needed.
Signed-off-by: Andrzej Głąbek <andrzej.glabek@nordicsemi.no>
The change in this commit is required to avoid regression errors
on EBQ test for the PHY update procedure
When in the peripheral role transmission of data must be resumed
while waiting for the PHY IND response from peer.
In other words: in the LP_PU_STATE_WAIT_TX_ACK_PHY_REQ state
data transmission must resume when acting as peripheral,
but not when in the central role
Following tests are effected
LL/CON/PER/BV-49-C
LL/CON/PER/BV-50-C
LL/CON/PER/BV-52-C
LL/CON/PER/BV-53-C
LL/CON/PER/BV-54-C
LL/CON/PER/BV-55-C
LL/CON/PER/BV-56-C
LL/CON/PER/BV-58-C
Signed-off-by: Andries Kruithof <andries.kruithof@nordicsemi.no>
This PR fixes the PHY update procedures for conformance tests when
being a Central
The problem was that data was in the LLL tx queue and was still being
queued before the PHY IND was queued (with a given instant).
As a result by the time the PHY IND was transmitted over the air the
instant was in the past.
The fix is to ensure that the LLL tx queue is empty, and to stop
queueing new data before queueing the PHY IND
Following tests are fixed:
LL/CON/CEN/BV-49-C
LL/CON/CEN/BV-50-C
LL/CON/CEN/BV-53-C
LL/CON/CEN/BV-54-C
Signed-off-by: Andries Kruithof <andries.kruithof@nordicsemi.no>
Complete the remote initiated version exchange if a LL_VERSION_IND is
received while already having responded in an earlier version exchange
procedure.
Clarify comment regarding how to handle this invalid behaviour.
This has been seen when running the LL/CON/CEN/BI-12-C test on EBQ.
Signed-off-by: Thomas Ebert Hansen <thoh@oticon.com>
Calculation of the DLE related parameters (rx/tx octets and time) depend
on the actual phy in use. For this reason the PHY settings must be
initialised before doing the DLE parameter calculations
Signed-off-by: Andries Kruithof <andries.kruithof@nordicsemi.no>
On remote terminate on central the conn clean-up would happen before ack
of terminate ind was sent to peer.
Now clean-up is 'postponed' until subsequent event.
Also now data tx is paused on rx of terminate ind to ensure no data is
tx'ed after rx of terminate ind
Signed-off-by: Erik Brockhoff <erbr@oticon.com>
On disconnect with refactored LLCP, if data tx is paused,
possibly 'waiting' tx nodes would not get released.
Signed-off-by: Erik Brockhoff <erbr@oticon.com>
Only apply change to effective DLE times if current max times are too
small to accommodate. Similar to legacy implementation
Update unit tests to new DLE ntf behavior
Signed-off-by: Erik Brockhoff <erbr@oticon.com>
Encryption request is enqueued in thread context from the Tx
buffer pool, so that it is serialized alongwith the already
enqueued data buffers ensuring they are transmitted out to
peer before encryption is setup. Allocate additional Tx
buffers to accommodate simultaneous encryption setup across
active connections.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
- Prevent NULL-pointer dereferencing if datapath is created late
- Support SDU fragment complete-counting for framed case
Signed-off-by: Morten Priess <mtpr@oticon.com>
Implemented incrementing TX SDU fragment count such that it indicates
the number of completed SDU fragments in the PDU being emitted for both
unframed and framed transmission.
Signed-off-by: Nirosharn Amarasinghe <niag@demant.com>
HCI:
-- Discarded data from HCI ISO Data packets from controller to host if
data has been lost
ISO-AL:
-- Corrected iso_interval in latency calculations
-- Updated handling and release of SDUs for error conditions / padding
at the last PDU for the SDU
-- Updated prioritisation of error status in released PDUs
-- Included error spooling exit on based on payload number to SDU
mapping for unframed reassembly
-- Updated sequence number handling for framed recombination
Signed-off-by: Nirosharn Amarasinghe <niag@demant.com>
Do not use ull_ticker_stop_with_mark for ISO one-shot resume ticker, but
stop without checking result. If active this will stop it, otherwise it
is ignored. Also, this prevents calling lll_disable twice.
Signed-off-by: Morten Priess <mtpr@oticon.com>
- Prioritize CIS_REQ handling in (old) LLCP
- Reject if CIS_REQ uses exisiting CIS ID
These fixes prevent assertions in /LL/CIS/PER/BV-38-C.
Signed-off-by: Morten Priess <mtpr@oticon.com>
Implementing proper validation of PHY selection for PHY UPDATE procedure
Implement connection termination on PHY UPDATE with instant in the past
Signed-off-by: Erik Brockhoff <erbr@oticon.com>
Replace k_sem_take loop used for consuming the remaining
sem give counts with k_sem_reset.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Fix assertion due to multiple mayfly_enqueue calls used
under ZLI when pdu_free_sem_give is invoked from the LLL.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
The Configure Data Path command must be included when the read Local
Supported Codecs [v2] command is supported. The Configure Data Path
command is needed when vendor-specific ISO data paths are supported,
but not otherwise tied to ISO. The respective weak function is
therefore moved to ull.c.
Signed-off-by: Wolfgang Puffitsch <wopu@demant.com>
When supporting chain PDUs, after HCI reset the first PDU
allocated did not initialize its next pointer causing use
of unallocated PDUs for chaining while a duplicate of such
PDU buffer being allocated for other states/roles. This
causes in certain cases both Extended and Periodic PDUs
having same data, the Extended Advertising PDU being
transmitted at the instant of the Periodic Advertising.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Fix BT_CTLR_RX_ENQUEUE_HOLD implementation that stalled
generating the CONN_UPDATE and PHY_UPDATE when there were
no Rx data or Tx acknowledgements to be processed when
the controller was built with BT_CTLR_LOW_LAT_ULL.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Add Kconfig option to conditionally enable tickers with slot
window to yield to normal tickers and be placed at the end
of their slot window if possible.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
The open source controller did not expose support for shutting it down
via the close() API in the HCI driver. Add support for it, which
completes the support for disabling and enabling the Bluetooth stack in
Zephyr.
Closes#3192.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Allow the controller to be deinitialized, adding the whole chain of
calls:
- ll_deinit()
- lll_deinit()
- lll_clock_deinit()
in order to be able to turn everything off, including the controller's
refcount of the LF clock.
Signed-off-by: Carles Cufi <carles.cufi@nordicsemi.no>
Fix Data Length Request CMD parameter checking to not
restrict invalid maximum Tx time values. This addresses
conformance test cases that provide maximum Tx time values
of 2128 us when not supporting Coded PHY in the Controller
implementation.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
If there is a PHY change on a connection it may happen that effective
RX and TX time changes also. That change is applied after an instant.
Implemented handling of effective time calculation is based on the
maximum PDU length, new PHY and local (default) maximum TX or RX time.
The maximum TX value is set to default one that corresponds to PHY 1M
during the Controller initialization. It can be updated by host to other
value. By default Zephyr Host updates it to max possible TX time for all
supported PHYs. If PHY CODED is enabled, it is the longest possible TX
duration 17040 us.
The maximum RX value is set to default during connection creation.
In case of use of legacy advertising, the value is also related with
PHY 1M. It can be updated by data length extension procedure.
If the maximum RX value is set to some value and there is a change
of a PHY to one that requires more time to send a PDU with the same
length, then the maximum RX value is wrongly calculated.
Function pu_calc_eff_time returns a value that is the default_time
argument. The problem is that the default_time should be adjusted
to new maximum RX time required for a new PHY.
To solve that there should be an evaluation of a new maximum RX and
TX time based on new PHY.
The commit adds missing evaluation.
The problem occurred in DF tests that check collision mitigation
between PHY update control procedure and CTE request control procedure.
There was missing CONFIG_BT_CTLR_PHY_CODED option in CTE request
unit tests. The code was working because the ULL implementation of
PHY change control procedure does not verify if PHY CODED is supported.
When missing support was enabled, tests showed wrong evaluation of
maximum RX time. It also unveiled error in CTE request unit tests
implementation. The default_tx_time was set to wrong value 2120 us
as if PHY CODED was not supported. To fix it, the value was changed
to PDU_DC_PAYLOAD_TIME_MAX_CODED.
There was also added a mock for a feature exchange procedure done
during unit tests setup step. That allows to correctly calculate
maximum TX time by ull_dle_max_time_get function.
Signed-off-by: Piotr Pryga <piotr.pryga@nordicsemi.no>
Fix filter accept list and privacy feature Kconfig default
based on whether host has them enabled.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Fix missing BT_CTLR_PRIVACY conditional compilations that
included redundant HAL code when Controller privacy is
disabled.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Fix PHY update procedure to handle unsupported PHY requested
by peer central device. PHY update complete will not be
generated to Host, connection is maintained on the old
PHY and the Controller will not respond to PDUs received on
the unsupported PHY.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Fixes issue re. sending packets after sending TERMINATE_IND.
Fixes issue re. erroneous error code on 'timed out' termination (ie
when peer does not ack terminate_ind)
Signed-off-by: Erik Brockhoff <erbr@oticon.com>
On a completion of feature exchange the max DLE times needs to be
updated if Coded PHY has become supported.
For this now also keep a separate store of the default_tx_octets/time
for the sake of re-calculation of local versions of DLE values
Signed-off-by: Erik Brockhoff <erbr@oticon.com>
Fix prepare pipeline from not resuming non-resume events
in pipeline when more than one resume events are present
before a non-resume event.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
When host issue HCI Reset controller should clear LE Static Random
address. Otherwise controller may incorrectly use one from before
HCI reset insread of rejecting HCI commands.
This was affecting following qualification test cases:
HCI/CCO/BI-51-C
HCI/CCO/BI-53-C
HCI/CCO/BI-54-C
HCI/CCO/BI-56-C
HCI/DDI/BI-06-C
HCI/DDI/BI-07-C
Signed-off-by: Szymon Janc <szymon.janc@codecoup.pl>
At least one supported PHY bit shall be set and none of
non-supported or RFU bits should be set.
This was affecting HCI/DDI/BI-05-C qualification test case.
Signed-off-by: Szymon Janc <szymon.janc@codecoup.pl>
Removes label experimental for direction finding feature in
Bluetooth Controller.
The feature stays disabled by default because it requires additional
dedicated hardware to be used. Besides that it significantly enlarges
amount of memory used by the Controller.
End user has to enable the feature explicitly by use of configuration
options.
Signed-off-by: Piotr Pryga <piotr.pryga@nordicsemi.no>
Fix preempt timeout scheduling to not skip first prepare in
pipeline when there are no previous preempt timeout
scheduled already.
Fix related to commit 27b8beaa22 ("Bluetooth: Controller:
Fix to handle relative short preempt timeout").
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
Maximum number of CTE to be send in a periodic advertising chain is
limited by BT 5.3 Vol 4 Part E, section 7.8.80 and is 16.
Maximum number of samples CTE in a periodic advertising chain is
limited by BT 5.3 Vol 4 Part E, section 7.8.82 and is also 16.
Both values are limited by amount of memory reserved in Controller
by Kcofigs, respectfully: CONFIG_BT_CTLR_DF_PER_ADV_CTE_NUM_MAX and
CONFIG_BT_CTLR_DF_PER_SCAN_CTE_NUM_MAX.
Functions ll_df_set_cl_cte_tx_params and ll_df_set_cl_iq_sampling_enable
check limits against Bluetooth specification provided values.
That can end with memory overwrite if number of requested CTEs is
greater that number provided in configuration.
The commit changes mentioned functions to validate HCI commands
parameters against configuration values.
Signed-off-by: Piotr Pryga <piotr.pryga@nordicsemi.no>
In case there are pending two control procedures: local and remote,
and remote device sends LL_REJECT_IND PDU then assertion happened.
ull_cp_rx function triggers assertion because LL_REJECT_IND is
considered as expected packet for all local and remote control
procedures.
That is not correct. It does not allow local procedure to handle
a response and stops a device on assert.
A remote device should not send LL_REJECT_IND PDU for locally initiated
control procedures, hence local device should not expect to receive
LL_REJECT_IND PDU to be expected one for pending remote control
procedure.
Remote device is allowed to send LL_REJECT_EXT_IND PDU for a locally
initiated control procedures. The LL_REJECT_EXT_IND PDU has a Reject-
Opcode that identifies rejected control procedure, hence is may be
expected by local device.
The commit provides changes that prevent the Controller assertion
in described case.
Signed-off-by: Piotr Pryga <piotr.pryga@nordicsemi.no>
CCM during on-the-fly decryption of a received packet starts decryption
when Radio triggers EVETNS_ADDRESS. In case there is possibility a
packet may include Constant Tone Extension, on-the-fly parsing of a
received packet for CTEInfo is enabled.
If there is a PHY 1M enabled the Radio stores received bits with a
delay, that is equal to time required to receive 3 bits. CCM TASKS_CRYPT
related with packet decryption should be delayed by the time the Radio
needs to store received data.
The commit provides changes required to delay start of the CCM
TASKS_CRYPT. It uses NRF_RADIO Bit counter feature. The Bit counter is
configured to trigger NRF_RADIO->EVENTS_BCMATCH on reception of 3rd bit.
The event is connected through PPI with CCM TASKS_CRYPT.
The PPI used is shared with Radio Rate override. That is possible because
direction finding feature is not allowed on PHY Coded and CCM needs a delay
only when used PHY 1M.
Signed-off-by: Piotr Pryga <piotr.pryga@nordicsemi.no>
lll_conn_rx_pkt_set function is called before one of radio_switch-
_complete_XXX functions calls in lll_peripheral.c. That prevents
lll_conn_rx_pkt to call any Radio setup related function that touches
NRF_RADIO->SHORTS. NRF_RADIO->SHORTS are assigned in radio_switch_-
complete_XXX functions, hence any change operation on the register done
before is overwritten.
Signed-off-by: Piotr Pryga <piotr.pryga@nordicsemi.no>
Add initial support for Periodic Advertising Data fragment
operation support.
This commit is limited to detection of partial data if used
before Periodic Advertising is enabled, which will lead to
HCI error reason of command disallowed.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
When resolving collision if ticks_slot_window is set for
either of the ticker then skip and such ticker be
rescheduled outside the collision within the
ticks_slot_window.
Signed-off-by: Vinayak Kariappa Chettimada <vich@nordicsemi.no>
[140/235] Building C object zephyr/subsys/bluetooth/controller/
CMakeFiles/subsys__bluetooth__controller.dir/ll_sw/ull_sched.c.obj
In file included from zephyr/subsys/bluetooth/controller/ll_sw/
ull_sched.c:28:
zephyr/subsys/bluetooth/controller/ll_sw/nordic/lll/lll_adv_pdu.h:
In function 'lll_adv_pdu_linked_next_get':
zephyr/subsys/bluetooth/controller/ll_sw/nordic/lll/lll_adv_pdu.h:8:32:
warning: implicit declaration of function 'MROUND'
[-Wimplicit-function-declaration]
8 | #define PDU_ADV_MEM_SIZE MROUND(PDU_AC_LL_HEADER_SIZE + \
| ^~~~~~
zephyr/subsys/bluetooth/controller/ll_sw/nordic/lll/lll_adv_pdu.h:12:11:
note: in expansion of macro 'PDU_ADV_MEM_SIZE'
12 | PDU_ADV_MEM_SIZE - \
| ^~~~~~~~~~~~~~~~
zephyr/subsys/bluetooth/controller/ll_sw/nordic/lll/lll_adv_pdu.h:197:9:
note: in expansion of macro 'PDU_ADV_NEXT_PTR'
197 | return PDU_ADV_NEXT_PTR(pdu);
Signed-off-by: Szymon Janc <szymon.janc@codecoup.pl>