Fix multiple issues related to the way the host handles
Identity Information related to privacy
1. If the controller provided a public address the IRK
for this identity would be randomly generated but not
stored persistenly.
2. Fix the handling of the above issue which was fixed
for the random address but would initiate settings save
ID on every boot.
3. Fix the host not using the Vendor Specific HCI commands
related to retrieving the Identity Root (IR) from the
controller and using the key diversified function d1
to generate an IRK as specified in the BT Core spec.
Make sure that a Host generated ID is only saved when it is first
generated.
Signed-off-by: Joakim Andersson <joakim.andersson@nordicsemi.no>
Fix missing log_strdup when loading bt/name setting. It should be done
on every string which is not in read only memory.
Signed-off-by: François Delawarde <fnde@oticon.com>
The CONFIG_* prefix was missing, making the #ifdef always false.
Found with a script (CONFIG_BT_SETTINGS_USE_PRINTK was unused).
Signed-off-by: Ulf Magnusson <Ulf.Magnusson@nordicsemi.no>
Some modules use snprintk to format the settings keys. Unfortunately
snprintk is tied with printk which is very large for some embedded
systems.
To be able to have settings enabled without also enabling printk
support, change creation of settings key strings to use bin2hex, strlen
and strcpy instead.
A utility function to make decimal presentation of a byte value is
added as u8_to_dec in lib/os/dec.c
Add new Kconfig setting BT_SETTINGS_USE_PRINTK
Signed-off-by: Kim Sekkelund <ksek@oticon.com>
Fix an issue where the generated identity was not permanently stored.
This resulted in being unable to reconnect after bonding when using
privacy, since a new local IRK was generated on reboot.
When settings is enabled the application is responsible for loading
identities and possible creating its own identities.
When settings_load is called and no identities has been created or found
in persistent storage a new identity will be created.
Since bt init has not been finalized bt_id_create will not make a call
to bt_settings_save_id. So we need to make sure that this identity will
be stored.
Signed-off-by: Joakim Andersson <joakim.andersson@nordicsemi.no>
Updated the bluetooth module to use static handlers. Removed the
old bt specific static registration.
The routine bt_settings_init() is still calling settings_init() which
IMO is not needed anymore.
Updates:
changed SETTINGS_REGISTER_STATIC() to SETTINGS_STATIC_HANDLER_DEFINE()
changed settings_handler_stat type to settings_handler_static type
removed NULL declarations
renamed bt_handler to bt_settingshandler, as bt_handler already exists.
renamed all bt_XXX_handler to bt_xxx_settingshandler to avoid any
overlap.
changed SETTINGS_STATIC_HANDLER_DEFINE() to create variable names from
_hname by just prepending them with settings_handler_.
updated all bt_xxx_settings_handler to just bt_xxx.
Signed-off-by: Laczen JMS <laczenjms@gmail.com>
This updates all client modules to const char processing of
setting names.
Update of peripheral_dis sample
Signed-off-by: Laczen JMS <laczenjms@gmail.com>
settings_read_cb is defined to return ssize_t and not size_t. This
also eliminates several Coverity warnings.
Fixes#15765Fixes#15768Fixes#15771Fixes#15774Fixes#15778
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Major changes are:
- Expose settings backend API to enable custom backend support.
- Add a new CONFIG_SETTINGS_CUSTOM backend to allow registering a custom
backend.
- Change api of the handlers h_set() routines to allow for
backend-specific read callbacks.
- Provide a customizable settings_backend_init() routine for custom
backends.
- Move runtime settings support to be its own backend.
Signed-off-by: François Delawarde <fnde@oticon.com>
Custom handlers without any arguments don't since there is a check for
argc > 1, to fix this behavior removing the check.
Signed-off-by: Luiz Augusto von Dentz <luiz.von.dentz@intel.com>
Add error checking, remove redundant code, and improve the logging for
settings related functionality.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The treatment of the BT_DEV_READY flag was broken when used together
with BT_SETTINGS. The flag would get set even though the stack was
still in a partially initialized state. Even worse, for central role
the stack would potentially try to initiate passive scanning without
having an identity address.
Refactor the code that sets the BT_DEV_READY flag (among other
initialization) into a separate bt_finalize_init() helper function and
call it when the settings have been loaded. Also clarify the warning
message given to the user in case settings_load() needs to be called.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Prevent temporary strings from being printed incorrectly if they go out
of scope before being processed by logger.
Signed-off-by: Filip Kubicz <filip.kubicz@nordicsemi.no>
The bt_settings_encode_key() cannot know if the given path pointer is
on the stack or not, so the only safe way to pass it to the logger is
by using a log_strdup() call. Not doing this will likely cause
corrupted strings to show up in the log output.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The Code need to be align after introduction of stream codec to
setting serialization subsystem.
Signed-off-by: Andrzej Puzdrowski <andrzej.puzdrowski@nordicsemi.no>
The return of memset is never checked. This patch explicitly ignore
the return to avoid MISRA-C violations.
The only directory excluded directory was ext/* since it contains
only imported code.
Signed-off-by: Flavio Ceolin <flavio.ceolin@intel.com>
Update the storage handling to take into account multiple identities.
We can save a bit of code by using the new bt_id_create() API from
within settings.c.
Also make the treatment of addr & irk parameters to bt_id_create()
consistent, in that NULL is acceptable for both of them.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This flag was both redundant and creates confusion with potentially
multiple identity addresses (it was only referring to the first
identity address). We can simply just look at the type of the identity
address wanting to be used.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Make it possible to have multiple identity addresses as an LE
peripheral. For central role only the default identity is supported
for now. This also extends the flash storage in a backward compatible
way.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Settings consider the character space the end of the value, so instead
encode the name using settings_str_from_bytes and restore it with
settings_bytes_from_str.
Signed-off-by: Luiz Augusto von Dentz <luiz.von.dentz@intel.com>
This uses bt_dev to store the name and allow changing it at runtime, in
addtion to that if CONFIG_BT_SETTINGS is defined make the name
persistent.
Fixes#8357
Signed-off-by: Luiz Augusto von Dentz <luiz.von.dentz@intel.com>
We should check for valid lengths, not just because flash may have
become corrupted, but also because this fixes coverity errors, such as
CID 186030.
Fixes#7739
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Integrate the bt_keys submodule with bt_settings. Add a new
bt_keys_store() API to write keys to flash, and extend the existing
bt_keys_clear() to remove the keys from flash.
Along with this, add some helpers for genrating settings key values
containing a bluetooth address, as well as for decoding them to get
the binary bt_addr_le_t.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Add a new linker section for a list of submodule settings handlers,
and iterate the list from the various settings callbacks.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The same functionality is now supported by the settings-based
solution, so remove bt_storage out of the way. There were stubs in
bt_storage to handle per-peer information (e.g. pairing keys) but this
was never actually implemented in full. The next step is to add this
support to the settings-based solution.
Leave the code for generating temporary IRK and identity address in
case BT_SETTINGS is not enabled. Also leave the code for using vendor
HCI to read the identity address, in which case the settings
implementation will not touch it.
Introduce a new bt_unpair() API to replace the removed
bt_storage_clear(), since the latter was actually doing more than just
storage management: it was also handling runtime storage of pairing
information. Later, the bt_unpair() implementation will be extended to
clear settings-based pairing storage.
There is one feature that the bt shell module looses: the ability to
give a specific identity address to the "init" command as a parameter.
We might look later in the future if this is really needed, and add a
separate API for this.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Introduce a basic skeleton for peristent storage based on the settings
subsystem. Also enable support for this to the peripheral sample
application, so the new code gets exersized by CI. For now, the
implementation provides the same level support as the bt_storage API
ever did, i.e. for the identity address and the IRK.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>