Now that device_api attribute is unmodified at runtime, as well as all
the other attributes, it is possible to switch all device driver
instance to be constant.
A coccinelle rule is used for this:
@r_const_dev_1
disable optional_qualifier
@
@@
-struct device *
+const struct device *
@r_const_dev_2
disable optional_qualifier
@
@@
-struct device * const
+const struct device *
Fixes#27399
Signed-off-by: Tomasz Bursztyka <tomasz.bursztyka@linux.intel.com>
Re-run with updated script to convert integer literal delay arguments to
k_sleep to use the standard timeout macros.
Signed-off-by: Peter Bigot <peter.bigot@nordicsemi.no>
move misc/util.h to sys/util.h and
create a shim for backward-compatibility.
No functional changes to the headers.
A warning in the shim can be controlled with CONFIG_COMPAT_INCLUDES.
Related to #16539
Signed-off-by: Anas Nashif <anas.nashif@intel.com>
move sensor.h to drivers/sensor.h and
create a shim for backward-compatibility.
No functional changes to the headers.
A warning in the shim can be controlled with CONFIG_COMPAT_INCLUDES.
Related to #16539
Signed-off-by: Anas Nashif <anas.nashif@intel.com>
Some device include a temperature sensor, usually used as a
companion for helping in drift compensation, that measure the
die temperature. This temperature IS NOT related to the the
ambient temperature, hence a clean separation between the two
is required.
This commit introduces a clean separation between the two
types of temperature leaving the old deprecated definition
still there.
The list of current drivers that read the die (and not the ambient)
temperature is the following:
- adxl362
- bma280
- bmg160
- bmi160
- fxos8700
- lis3mdl
- lsm6ds0
- lsm6dsl
- lsm9ds0
- mpu6050
Signed-off-by: Armando Visconti <armando.visconti@st.com>
Based on the discussion in #5693, the reason why humidity was defined
in milli-percent was likely following Linux which defines it as such
in its sensor subsystem:
http://elixir.free-electrons.com/linux/latest/source/Documentation/ABI/testing/sysfs-bus-iio#L263
However, Linux defines temperature in milli-degrees either, but
Zephyr uses degrees (similarly for most other quantities). Typical
sensor resolution/precision for humidity is also on the order of 1%.
One of the existing drivers, th02.c, already returned values in
percents, and few apps showed it without conversion and/or units,
leading to confusing output to user like "54500".
So, switching units to percents, and update all the drivers and
sample apps.
For few drivers, there was also optimized conversion arithmetics
to avoid u64_t operations. (There're probably more places to
optimize it, and temperature conversion could use such optimization
too, but that's left for another patch.)
Fixes: #5693
Signed-off-by: Paul Sokolovsky <paul.sokolovsky@linaro.org>
This commit provides sample application for sensor hts221.
By default, it is enabled on board disco_l475_iot1
Change-Id: I535fac8a670fa89cc1cae15ea1abe9cfe4b6c56b
Signed-off-by: Erwan Gouriou <erwan.gouriou@linaro.org>