Added the stop_bits_client parameter to the modbus_serial_param struct.
Being able to configure the number of stop bits for the client
independently from the parity setting, allows to support connecting to
modbus server that do not follow the MODBUS over Serial Line Specification
and Implementation Guide.
Signed-off-by: Constantin Krischke <constantin.krischke@lemonbeat.com>
Signed-off-by: Jan Geldmacher <jan.geldmacher@lemonbeat.com>
For functions returning nothing, there is no need to document
with @return, as Doxgen complains about "documented empty
return type of ...".
Signed-off-by: Daniel Leung <daniel.leung@intel.com>
Prefix internal functions and structs with modbus_.
Use unit_id consistently instead of node_addr.
Fix mbm_ remainder and rename to mbc_.
Rename struct modbus_frame to modbus_adu since
ADU is closer to what the structure represents.
Let the compiler/linker do the job and
remove ifdef around mbc_validate_fc03fp_response().
Signed-off-by: Johann Fischer <johann.fischer@nordicsemi.no>
Add function to get Modbus RTU interface index according
to interface name. This can be used to clearly identify
interfaces in the application.
Signed-off-by: Johann Fischer <johann.fischer@nordicsemi.no>
Add MODBUS RTU (over serial line) subsystem.
MODBUS RTU implementation supports booth server and
client roles. Some components of the implementation are based
on the uC/Modbus stack, which was published under Apache license,
(https://github.com/SiliconLabs/uC-Modbus
fdd1218a28e313c1212fed5ed42e5c65d3056a2c).
Resolves: #2854
Signed-off-by: Johann Fischer <j.fischer@phytec.de>