Commit Graph

20 Commits

Author SHA1 Message Date
Maksim Salau
bdd94261a5 modbus: serial: Add non-compliant mode with custom stop-bit settings
The mode is activated by the CONFIG_MODBUS_NONCOMPLIANT_SERIAL_MODE option
and allows any stop-bit setting for the serial port.

Signed-off-by: Maksim Salau <msalau@iotecha.com>
2025-06-10 12:53:23 -04:00
Federico Di Gregorio
f8ab959d7e boards: opta: RS485 support
This set of changes enables the RS485 hardware connected to usart3 and
provides some overlays that allow for easily running the modbus
rtu_client and rtu_server samples on Opta.

Signed-off-by: Federico Di Gregorio <fog@dndg.it>
2024-11-20 15:59:53 -05:00
Johann Fischer
47c8815253 modbus: fix support for floating point values
The Modbus protocol object types are either single-bit or 16-bit word.
Other types are not defined in the specification. Types such as float
are typically mapped to two 16-bit registers. Current implementaiton
does not maps correctly to the 16-bit word addresses. On the client
side, the implementation must take into account that the number of
requested registers (Quantity of Registers) is double that of a "float"
register.  The server side should not treat "Quantity of Registers" and
"Byte count" differently for addresses reserved for floating values,
only in the user callback the two 16-bit registers are mapped to a float
value but still aligned to 16-bit register addresses.

Signed-off-by: Johann Fischer <johann.fischer@nordicsemi.no>
2024-10-08 17:01:19 +02:00
Anas Nashif
345735d0a8 tests: remove CONFIG_ZTEST_NEW_API in all tests
Remove all usage of CONFIG_ZTEST_NEW_API from tests and sample as this
is now enabled by default.

Signed-off-by: Anas Nashif <anas.nashif@intel.com>
2023-10-20 15:04:29 +02:00
Anas Nashif
0064b6e8b6 tests: samples: cleanup test tags, add integration_platforms
Use integration platforms and sanitize tags.

Signed-off-by: Anas Nashif <anas.nashif@intel.com>
2023-06-02 04:47:06 -04:00
Parthiban Nallathambi
75479f5338 modbus: add user data for adu callback
add user data for adu callback, which helps in passing
socket and relevant application parameters.

Signed-off-by: Parthiban Nallathambi <parthiban@linumiz.com>
2022-09-02 10:51:57 +02:00
Johann Fischer
9a1b990006 modbus: remove label property from devicetree overlays
Remove label property from devicetree overlays.

Signed-off-by: Johann Fischer <johann.fischer@nordicsemi.no>
2022-08-11 09:39:24 -07:00
Johann Fischer
46a0e5347d modbus: remove the use of DT_INST_LABEL and DT_PROP(inst, label)
Although it is possible to simply use the interface number,
it has proven convenient to use the names for the interfaces
in the samples.

Migrate to DEVICE_DT_NAME().

Signed-off-by: Johann Fischer <johann.fischer@nordicsemi.no>
2022-08-11 09:39:24 -07:00
NingX Zhao
cadb0802bf tests: subsys: modbus cases move to new ztest API
Move test to use new ztest API.

Signed-off-by: NingX Zhao <ningx.zhao@intel.com>
2022-08-08 10:51:17 +02:00
Fabio Baltieri
def230187b test: fix more legacy #include paths
Add a bunch of missing "zephyr/" prefixes to #include statements in
various test and test framework files.

Signed-off-by: Fabio Baltieri <fabiobaltieri@google.com>
2022-08-02 16:41:41 +01:00
Gerard Marull-Paretas
ade7ccb918 tests: migrate includes to <zephyr/...>
In order to bring consistency in-tree, migrate all tests to the new
prefix <zephyr/...>. Note that the conversion has been scripted, refer
to #45388 for more details.

Signed-off-by: Gerard Marull-Paretas <gerard.marull@nordicsemi.no>
2022-05-06 20:02:14 +02:00
Constantin Krischke
8ee675946c modbus: stop bits can now be set individually in client mode
Added the stop_bits_client parameter to the modbus_serial_param struct.
Being able to configure the number of stop bits for the client
independently from the parity setting, allows to support connecting to
modbus server that do not follow the MODBUS over Serial Line Specification
and Implementation Guide.

Signed-off-by: Constantin Krischke <constantin.krischke@lemonbeat.com>
Signed-off-by: Jan Geldmacher <jan.geldmacher@lemonbeat.com>
2022-03-24 08:23:17 -04:00
Anas Nashif
97af0c8c33 tests: remove subsys prefix from test identifier
No need for subsys, the subsystem is expected to be the first component
of the identifier.

Signed-off-by: Anas Nashif <anas.nashif@intel.com>
2022-03-18 10:50:57 -04:00
Johann Fischer
ca6f24d36f tests: modbus: correct test fixture description
Correct test fixture description for FRDM-K64F board.

Signed-off-by: Johann Fischer <johann.fischer@nordicsemi.no>
2022-02-15 18:56:36 +01:00
Johann Fischer
906274e94e tests: modbus: add test fixture
Test fixture is required for the test on FRDM-K64F board.

Signed-off-by: Johann Fischer <johann.fischer@nordicsemi.no>
2022-02-09 22:11:16 -05:00
Torsten Rasmussen
1cccc8a8fe cmake: increase minimal required version to 3.20.0
Move to CMake 3.20.0.

At the Toolchain WG it was decided to move to CMake 3.20.0.

The main reason for increasing CMake version is better toolchain
support.

Better toolchain support is added in the following CMake versions:
- armclang, CMake 3.15
- Intel oneAPI, CMake 3.20
- IAR, CMake 3.15 and 3.20

Signed-off-by: Torsten Rasmussen <Torsten.Rasmussen@nordicsemi.no>
2021-08-20 09:47:34 +02:00
David Leach
8272b32708 tests: modbus: Fix potential memory overwrite (coverity)
Fixes #33816
Fixes #33811
Fixes #33793
Fixes #33797
Fixes #33796

Signed-off-by: David Leach <david.leach@nxp.com>
2021-04-01 04:52:10 -04:00
Johann Fischer
570a2f0839 tests: modbus: add raw ADU support test
Add raw ADU support test.

Signed-off-by: Johann Fischer <johann.fischer@nordicsemi.no>
2021-03-19 15:50:21 +01:00
Johann Fischer
4ff616b647 modbus: rework interface configuration
Use commot parameter structure to configure server
or client interfaces.

Signed-off-by: Johann Fischer <johann.fischer@nordicsemi.no>
2021-03-19 15:50:21 +01:00
Johann Fischer
5319c7b042 tests: modbus: remove _rtu_ from modbus test
Remove _rtu_ from modbus test.

Signed-off-by: Johann Fischer <johann.fischer@nordicsemi.no>
2021-03-19 15:50:21 +01:00