From 40abcd283cee7783cd103bed2db922e17941ca08 Mon Sep 17 00:00:00 2001 From: Gerard Marull-Paretas Date: Fri, 22 Apr 2022 12:29:32 +0200 Subject: [PATCH] boards: riscv: rv32m1_vega: fix PWM period and flags The PWM driven LEDs had a wrong period: 0 nsec. A value of 20 msec has been chosen as most other boards do for PWM driven LEDs. The polarity has been set to normal (LEDs are driven active high). Signed-off-by: Gerard Marull-Paretas --- boards/riscv/rv32m1_vega/rv32m1_vega.dtsi | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-) diff --git a/boards/riscv/rv32m1_vega/rv32m1_vega.dtsi b/boards/riscv/rv32m1_vega/rv32m1_vega.dtsi index 0a5ef324c80..93a3b1e7443 100644 --- a/boards/riscv/rv32m1_vega/rv32m1_vega.dtsi +++ b/boards/riscv/rv32m1_vega/rv32m1_vega.dtsi @@ -44,15 +44,15 @@ pwmleds { compatible = "pwm-leds"; blue_pwm_led: pwm_led_0 { - pwms = <&tpm2 2 0 0>; + pwms = <&tpm2 2 PWM_MSEC(20) PWM_POLARITY_NORMAL>; label = "User PWM LD1"; }; green_pwm_led: pwm_led_1 { - pwms = <&tpm2 1 0 0>; + pwms = <&tpm2 1 PWM_MSEC(20) PWM_POLARITY_NORMAL>; label = "User PWM LD2"; }; red_pwm_led: pwm_led_2 { - pwms = <&tpm2 0 0 0>; + pwms = <&tpm2 0 PWM_MSEC(20) PWM_POLARITY_NORMAL>; label = "User PWM LD3"; }; };